Gas monitoring: underground garages

KIMESSA gas detection systems for underground car parks

Modern society lives and works with toxic and combustible gases and vapours every day. Today gas represents an economic, technical and convenient medium, but left unchecked gas can rapidly become a significant hazard.

KIMESSA gas detection systems for underground car parks

CO/NO2 Gas detection systems

Typical gases present in underground car parks are: CO, NO2, NO and petrol vapours.

CO/NO2 measurement and control systems are therefore standard equipment in underground car parks and bus parking garages to regulate air quality and protect personnel. Energy efficient control of ventilation systems, safety and air quality are critical requirements in the provision of a gas monitoring system for underground car parks and garages. The new generation of versatile CANline gas monitor control units are a cost effective solution for small and large installations. Precise and selective measurement is a prerequisite for the best results. Innovative and tailored design of the CANline gas monitor enables versatile, convenient control of the ventilation system.

KIMESSA gas detection systems for underground car parks 345343

Individual ventilation protocols are created with user selected Kimessa control programs. The integrated fan activation and deactivation time delays prevent premature fan activation due to locally elevated CO concentrations (petrol vehicles) or NO2 concentrations (diesel vehicles). The quality and accuracy of CO/NO2 measurement is dependent on the detector measuring principle. KIMESSA CO/NO2 gas detectors are equipped with a selective electrochemical sensing element. This guarantees an effective optimum operation of the ventilation system while maintaining the required safety threshold from vehicle exhaust fumes.

Touch screens or Web servers can be used for the visualization and rapid control of gas monitoring data. All data is of course recorded and can be viewed locally on the touch display or via the Web browser on any PC.

Exhaust Gas Alarm Signs
The CO/NO2 gas concentration in an enclosed space can quickly increase due to heavy traffic movements or a vehicle engine malfunction and result in a potential poisoning hazard. Exhaust gas detection ‘gas alarm signs’ promptly alert any persons at risk to the presence of excessive gas concentrations in the ambient air. The ‘gas alarm signs’ are installation friendly and can be perfectly integrated in any enclosed space, even with sophisticated architecture. Symbols and text are used to convey the correct response to an exhaust gas alarm. The text is available in several languages and the design of the ‘gas alarm sign’ can be individually adapted (height, pictogram, etc.).

kimessa

On request the complete gas detection system including the ‘gas alarm sign’ can be provided with an emergency power supply.

The KIMESSA system allows for the option to integrate a UPS (uninterruptible power supply) to be integrated into the control cabinet and therefore does not require its own housing. Alternatively, we can install all items in a project-specific control cabinet.

KIMESSA gas detection systems for underground car parks 453635

Our gas detector housings are made of welded stainless steel, are extremely robust and offer excellent protections against vandalism, an unfortunate occurrence in public car parks. To differentiate the Kimessa BUS technology gas monitoring concept from our competitors; we also completely integrate the alarm activity into the BUS. For example, the LED warning lights and the alarm sounders can be integrated into the BUS. This means a significant saving in cable runs. A further advantage is that extensions or changes can be performed economically and new cable runs are possible at any time.

kimessa bus system

Differential moisture control solution for the dehumidification
of underground car parks
To overcome the problem associated with high humidity and damp conditions in underground car parks, Kimessa offers a differential moisture control solution for the dehumidification of underground car parks.
Provided that the air outside of the building is dryer than the air inside, the differential humidity control developed in-house by KIMESSA acts as an efficient space dehumidifier upon activation.

With differential moisture control, one humidity/temperature sensor is fitted in the enclosed space and a second humidity/temperature sensor is fitted outside the building. The two sensors are connected to the KIMESSA moisture controller, which is preferably installed in or next to the control cabinet.

The KIMESSA humidity control unit evaluates the sensor data and stops the fan as soon as the absolute humidity inside the building is higher inside than outside.

 

Technical Information – Differential humidity control

Download documentation for Underground car parks

Contact us       Next to product overview       Return to the application overview

Online inquiry form for CO/NO2 gas monitoring systems

In addition to the applications already described there are very many other areas of use for KIMESSA gas monitoring systems. As a total solution provider in the field of gas detection technology and gas detection we offer individual, tailor-made solutions for virtually any requirement of stationary gas detection. We will show you technically sophisticated gas monitoring solutions which you can rely on at all times.